Technische Daten |
Nominal Battery Voltages |
12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) |
Maximum Output Current |
80 amps @ 104º F (40ºC) with adjustable current limit |
Maximum Solar Array STC Nameplate |
12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC Systems 7500 Watts |
NEC Recommended Solar Array STC Nameplate |
12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts |
PV Open Circuit Voltage (VOC) |
150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum |
Standby Power Consumption |
Less than 1 Watt typical |
Power Conversion Efficiency |
97.5% @ 80 Amps in a 48 VDC System - Typical |
Charging Regulation |
Five Stages: Bulk, Absorption, Float, Silent and Equalization |
Voltage Regulation Set points |
10 to 80 VDC user adjustable with password protection |
Equalization Charging |
Programmable Voltage Setpoint and Duration - Automatic Termination when completed |
Battery Temperature Compensation |
Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell |
Voltage Step-Down Capability |
Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input |
Programmable Auxilary Control Output |
12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) |
Status Display |
3.1in (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total |
Remote Display and Controller |
Optional Mate or Mate2 with RS232 Serial Communications Port |
Network Cabeling |
Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) |
Data Logging |
Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production |
Hydro Turbine Applications |
Consult factory for approved Turbines |
Positive Ground Applications |
Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) |
Operating Temperature Range |
Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C) |
Environmental Rating |
Indoor Type 1 |
Conduit Knockouts |
One 1 (35mm)on the back; One1 (35mm) on the left side; Two 1 (35mm) on the bottom |
Warranty |
Standard 5 year |
Weight |
Unit |
12.20 lbs (5.56 kg) |
|
Shipping |
15.75 lbs (7.10 kg) |
Dimensions |
Unit |
41.3 x 14 x 10 cm - (H x W x D) |
|
Shipping |
53 x 27 x 25 cm |
Options |
Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 |
Menu Languages |
English & Spanish |